DRI-CHEM NX700
A high throughput automatic clinical chemistry analyzer accommodating five different samples simultaneously.
Effortless testing at your fingertips
High throughput 190 tests/hour
28 colorimetric items, 3 electrolyte items
FUJI DRI-CHEM has earned a remarkable reputation from its continuous effort to provide timely testings.
So far, we have improved its usability and network adaptability. While retaining the main characteristics of its predecessor,
the NX700 provides one rank higher usability.
It can be operated intuitively, thus it is usable to anybody. Moreover, its compact design allows flexibility in installation.
NX700: borderless and effortless “Full-time, Real time Testing”
at anyone’s hands.
- Real walk-away system
- Maximum of 5 specimens in one operation
- Large touch panel and new operation interface
- Intuitive and simple operation
- No calibration needed*1 Simple lot compensation by QC card
DRI-CHEM for emergency: Supports diagnosis and treatment during disasters.
- It operates on 100-240V household power supply.
- No need of water, air supply and exhaust equipment. DRI-CHEM allows “full-time and real time” examinations in time of need.
The new design brings forth workflow evolution
Compact size, small footprint
NX700 is designed to be compact and suitable to almost any space.
Product dimensions
Width 500 mm | Weight of main unit 33 kg |
Depth 380 mm | |
Height 410 mm |
Large touch panel with simple design
A large touch panel is used for the operation screen. The sliding type front cover prevents unnecessary consumption of space and provides easy handling. The ease of use from the new design enables smoother operation. The exterior is specifically designed for better adaptability in any place.
Intuitive and simple operation
Simple and easy to use operational screen. Explanatory diagrams make the use, troubleshooting and the various maintenance procedures easy.

Setup screen

Display of results

Help screen
Easy Operation
![[photo] Gloved hand placing slide and specimen on internal tray inside incubator and then pressing start on external display/screen with machine lid closed](https://asset.fujifilm.com/www/in/files/2020-05/e25213203b6d8edf3f4b1e6b28132e32/pic_dri-chem-nx700_07.jpg)
3-Step easy measurement
Set the slide, the specimen and press the START key. All the processes hereafter are fully automated.
5 specimens can be set at the same time
A maximum of 5 specimens can be set at the same time. No manual operation after pressing START key. The automation shortens operation time and improves workflow efficiency.
Easy lot compensation by QC card
Corrections are made simply by reading the QC card included in the slide package into the main unit.
- * CRP: Calibration is required. ISE: QC card is not attached.
-
Safety and Convenience
Patient-friendly testing
Each test needs only 10μL of sample. (CRP needs 5μL/test, ISE needs 50μL/3 tests). Manual pipetting can be also performed when sample is less. Less invasive for newborn at NICU.
- * 50 μL are used for the simultaneous measurement of 3 electrolyte items.
Useful Functions
Plasma Filter: Blood separation in 1 minute
Plasma Filter (PF) can cut the turn around time and the pre-treatment process of the sample. It can generate plasma sample by aspirating and separating the whole blood inside the PF within 1 minute. Just set the PF on top of the sample tube and press START.
- * This function is not available in the NX700i
- * TCO2: not applicable
Easy CRP calibration
![[photo] Tray inside incubator with vials of CP-1, CP-2, and CP-3 calibration fluid on it](https://asset.fujifilm.com/www/in/files/2020-05/6fcb5ff4f3b4c49ba9cc22a1b1aefb15/pic_dri-chem-nx700_13.jpg)
Automatic dilution function
Labor intensive operations like dispensing, mixing etc. are automated. The only operation is to input the dilution ratio.
Electrolyte measurement function
Electrolytes (Na-K-Cl) can also be measured.
STAT testing available
Press the “STAT” key when there is ongoing measurement. Set the emergency specimen and just press START to perform emergency test.
HL7 communication
The NX700 can communicate using standard HL7 protocol.



Accurate and reliable test results from long term and field-proven technology & experience
The FUJI DRI-CHEM slide reagent has high reliability and stability brought by fine chemical technology cultivated through the long history of FUJIFILM in photographic film manufacturing.
Less variation of results between operators, high result reproducibility and daily precision, and excellent correlation with wet chemistry are its remarkable features.
FUJI DRI-CHEM SLIDE
Colorimetric method slide
(Enzymes, General chemistry, and Immunology)
This multilayered slide is composed of dry chemical ingredients needed for the reaction and other functional materials. It quantifies enzymes and chemicals using colorimetric method.
![[image] DRI-CHEM Slide composition of multilayered film - Spreading layer, Reflection layer, Reaction layer, Transparent support film, and Spectrophotometer](https://asset.fujifilm.com/www/in/files/2020-05/47e6d7b2c48954e2cf2edc90aede6167/fig_dri-chem-nx700_05.jpg)
Potentiometric method slide
(Electrolytes)
The electrolytes slide contains ion selective film electrodes for Na, K, and Cl. These electrolytes are measured by potentiometric method.
![[image] Potentiometric method electrolytes slide - electrode terminal, potentiometer, pertition materials, and multilayered film electrode](https://asset.fujifilm.com/www/in/files/2020-05/016b85e2f933e33164b102d20e7c0cf1/fig_dri-chem-nx700_06.jpg)
Specifications FUJI DRI-CHEM NX series
![]() |
![]() |
|
Series name | FUJI DRI-CHEM NX700 | FUJI DRI-CHEM NX500 |
Width × depth × height | 500(W) × 380(D) × 410(H) mm | 470(W) × 360(D) × 420(H) mm |
Weight | 33 kg | 25 kg |
Number of measurement cells | 13 colorimetric + 1 electrolyte (independent) | 12 colorimetric + 1 electrolyte (independent) |
Throughput (1) (only colorimetry) | 180 tests/hour | 120 tests/hour |
Throughput (2) (colorimetry + electrolytes) | 190 tests/hour | 128 tests/hour |
Throughput (3) (15-item measurements) | approx. 9 minutes | approx. 9 minutes |
Number of specimen that can be set | 5 specimens at the same time | 1 specimen |
Maximum memory of QC information/ parameter | 5 lots | 2 lots |